PMI Homes Plans

a-FIRST FLOOR 931' - 3 5/8" FIRST FLOOR CEILING 941' - 1 1/8" a-SECOND FLOOR 941' - 11 5/8" SECOND FLOOR CEILING 950' - 9 1/8" BASEMENT CEILING 930' - 5 1/8" BASEMENT FLOOR 920' - 8" 8" PRECAST PLANK 8" PRECAST PLANK 2x4 STUDS @ 16" O.C. W/ 1/2" SHEETROCK (TYPICAL) 1 1/2" GYP. CRETE 1" RIGID INSUL. 8" PRECAST PLANK 9' - 9 1/8" 9' - 9 1/2" 8' - 9 1/2" 0' - 6" SOFFIT TO MATCH EXIST. SOFFIT TO MATCH EXISTING 8" CONC. BLOCK STONE VENEER MATCH EXIST FASCIA MATCH EXIST SOFFIT W/ VENTS ROOF: MATCH EXIST SHINGLES 15# FELT 1" PLYTWOOD SHEATHING ROOF TRUSSES @ 24" O.C. (BY MFG) R-44 INSULATION 2X6 TRTD. PLATE 1/2"X12" A.B. @ 32" O.C. W/ SILL SEALER ALL CANTILEVERS, CORNERS, & RIMS TO BE COVERED W/ BUILDING PAPER PRIOR TO SIDING PROVIDE SOLID BLOCKING AT ALL SUPPORT BEAMS TO POINT LOADS VENT BAFFLES @ 24" O.C. 5/8" GYP. BD. W/ VAPPOR BARRIER VENT ROOF 1 -200 50% SOFFIT 50% ROOF DRAIN TILE AS REQD. ON 2' MIN. OF WASHED GRAVEL OR CRUSHED ROCK, AND COVERED W/ 6" OF SAME MATERIAL a-TUNNEL LEVEL 903' - 3" 12 8 2x4 TIMBERSTRAND STUDS @ 16" O.C. W/ SPRAY FOAM INSUL. (TYPICAL) 14" CONC. POURED 8" OF 6" POURED 10" CONC. POURED 14" CONC. POURED 10" CONC. POURED 1 1/2" GYP. CRETE 1" RIGID INSUL. 1 1/2" GYP. CRETE 1" RIGID INSUL. IN FLOOR HEAT IN FLOOR HEAT IN FLOOR HEAT 8" CONC. BLOCK LINE OF GUEST HOUSE W.O. LEVEL 6' - 8 7/8" 2" FURRING 3 1/2" CONC. FLOOR W/ POLY UNDER 4" OF 4" POURED 12" OF 8" POURED 20"x10" CONC. FTG. 6" ROCK ON SAND (TYPICAL) 32"x10" CONC. FTG. IN FLOOR HEAT 1' - 4" 12 8 1' - 7 3/8" 3' - 11 1/2" 1' - 8" 1/2" SHEETROCK 9' - 9 5/8" NEW 4" CONC. TOPPING RUBBER MEMBRANE 8" PRE-CAST PLANK 3 1/2" CONC. FLOOR W/ POLY UNDER 5/8" TYPE "X" GYP. BD. W/ V.B. SOFFIT TO MATCH EXISTING R-44 INSUL. REMOVE EXISTING O.H. 12 6 8" CONC. BLK. 9' - 6" 0' - 8" 9' - 4" 24"x8" CONC. FTG. 6" ROCK ON SAND (TYPICAL) REMOVE EXISTING WALL 16" CONC. BLK. 12" CONC. BLK. 32"x10" CONC. FTG. 12" CONC. BLK. BELOW GRADE 8" CONC. BLK. NEW GIRDER TRUSS 8" CONC. BLK. 16"x8" CONC. FTG. 9' - 9 1/2" 9' - 9 1/8" 8" PRE-CAST PLANK 8" PRE-CAST PLANK 1 1/2" GYP. CRETE 1" RIGID INSULATON SOFFIT TO MATCH EXISTING HOUSE MATCH EXIST FASCIA MATCH EXIST SOFFIT W/ VENTS ROOF: MATCH EXIST SHINGLES 15# FELT 1" PLYTWOOD SHEATHING ROOF TRUSSES @ 24" O.C. (BY MFG) R-44 INSULATION 2X6 TRTD. PLATE 1/2"X12" A.B. @ 32" O.C. W/ SILL SEALER ALL CANTILEVERS, CORNERS, & RIMS TO BE COVERED W/ BUILDING PAPER PRIOR TO SIDING PROVIDE SOLID BLOCKING AT ALL SUPPORT BEAMS TO POINT LOADS VENT ROOF 1 -200 50% SOFFIT 50% ROOF DRAIN TILE AS REQD. ON 2' MIN. OF WASHED GRAVEL OR CRUSHED ROCK, AND COVERED W/ 6" OF SAME MATERIAL 5/8" GYP. BD W/ V.B. 1/2" GYP BD. 8" CONC. BLOCK 3 1/2" CONC FLOOR W/ VAPOR BARRIER BASEMENT LEVEL AT HOUSE 2" RIGID INSUL. 3/4" PLYWOOD STUCCO FINISH 2x4 TIMBERSTRAND STUDS @ 16" O.C. W/ SPRAY FOAM INSUL. (TYPICAL) 12" CONC. BLOCK 32"x10" CONC. FTG. 8" CONC. BLOCK 1 1/2" GYP. CRETE 1" RIGID INSULATON IN FLOOR HEAT IN FLOOR HEAT IN FLOOR HEAT 8" CONC. BLOCK 36" HIGH W.I. RAILING TO MATCH EXISTING HOUSE TRTD 2x10 DECK RIM CONT. TRTD 3 1/2"x 11 7/8" P.L. DR. VENT BAFFLES @ 24" O.C. SADDLE W/ FULL ICE SHIELD 1/2" SHEETROCK 12 6 1ST FLOOR LINE AT HOUSE 6" ROCK ON SAND (TYPICAL) 12" CONC. BLOCK 32"x10" CONC. FTG. 9' - 9 5/8" 0' - 9 7/8" GRADE 4" CONC. TOPPING RUBBER MEMBRANE 8" PRECAST PLANK 8' - 0 1/2" IN FLOOR HEAT 3 1/2" CONC. FLOOR W/ POLY UNDER 6" ROCK ON SAND (TYPICAL) 12" CONC. BLOCK 28"x10" CONC. FTG. 1C-6" CONC. CURB 1'-0" SEALED SUMP BASKET MIN. 3" MIN. ABS OR PVC OR EQUIVALENT GASTIGHT PIPE (AF103.6.1) PROVIDE SPACE FOR FUTURE INSTALLATION OF A FAN (AF103.8) * MIN. 24" DIAMETER CENTERED ON THE AXIS OF THE VENT STACK * MIN. VERTICAL DISTANCE 36" INSTALL LIVE OUTLET IN ATTIC WHERE FUT. FAN MAY BE INSTALLED (AF103.12) INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOOR AND IN ACCESSIBLE ATTICS (AF103.4.5) MIN. 6 MIL OR 3 MIL CROSS LAMINATED POLY SHALL BE LAPPED 12" AND PLACED BELOW THE SLAB AND ON TOP OF 4" MIN. SAND GAS PERMEABLE LAYER SEAL ALL JOINTS BETWEEN SLAB AND FOUND. WALL SEAL ALL FLOOR OPENINGS ALL CONTROL JOINTS, ISOLATION JOINTS, CONSTRUCTION JOINTS, AND ANY OTHER JOINTS IN CONCRETE SLABS SHALL BE SEALED WITH CAULK OR SEALANT 8"X16" ROCK TRENCH (1"-1 1/2") 4" PERFORATED DRAIN TILE W/FILTER FABRIC ALL PIPE JOINTS AND FITTINGS TO BE GLUED OR TRANSITION COUPLINGS INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOOR AND IN ACCESSIBLE ATTICS (AF103.4.5) PER PLAN PER PLAN PER PLAN PER PLAN PER PLAN PER PLAN PLAN SUBMITTED UNDER 'ALTERNATIVE DESIGN' PER SECTION 1300.0110: SUBP 13 OF THE 2007 MN. STATE BLDG. CODE CONC. WALLS PER PLAN CONC. FOOTING PER PLAN REAL STONE VENEER 1x6 TRIM 2" RIGID INSULATION 3/4" PLYWOOD SHEATHING STUCCO FINISH FLASHING AS REQ. 3 1/2" CONC. FLOOR W/ POLY UNDER 6" OF ROCK ON SAND 2x4 TIMBERSTAND STUDS @ 16" O.C. W/ SPRAY FOAM IN FLOOR HEAT 1 1/2" GYP. CRETE 1" RIGID INSUL. 8" PRE-CAST PLANK 2x14 WINDOW BOX FOR WINDOW FRAMING 2" RIGID INSUL. 3/4" PLYWOOD STUCCO 1/2" SHEETROCK 2x4 TIMBERSTRAND STUDS @ 16" O.C. W/ SPRAY FOAM INSUL. 8" CONC. BLK. Fax: 763-780-8015 BLAINE, MN. 55449 SUITE 106 9100 BALTIMORE ST NE Phone: 763-780-8004 C D.F.P. PLANNING & DESIGN SHEET NO. COMM. NO. DRAWN BY: REVISIONS: DATE: 2010 DFP PLANNING & DESIGN UNAUTHORIZED USE OF THE PLAN IS A VIOLATION OF THE US COPYRIGHT ACT. 9 210120 AANENSON ADDITION 6-29-10 7-7-10 6-22-10 7-15-10 JJ 7-19-10 7-21-10 7-23-10 8-16-10 9-1-10 9-21-10 10-15-10 12-7-10 3288 OWASSO HEIGHTS NOTES: 1. WINDOW WELLS WITH A VERTICAL DEPTH OF MORE THAN 44" MUST BE EQUIPPED WITH AN APPROVED LADDER 2. ALL OPENINGS LESS THAN 4" @ ALL GUARDRAILS 3. GUARDRAIL REQUIRED ON OPEN SIDE OF ANY STAIR MORE THAN 30" ABOVE FLOOR 4. PROVIDE SMOKE DETECTORS IN EVERY BEDROOM AND THE CORRIDOR GIVING ACCESS TO THE BEDROOM, ON EACH FLOOR INCLUDING THE BASEMENT, AND IN ANY ROOM THAT HAS A CEILING HEIGHT MORE THAN 24" HIGHER THAN A CORRIDOR GIVING ACCESS TO THE BEDROOMS. 5. NOTE ON ALL PLANS * DBL STUDS @ ALL WINDOWS AND PATIO DOOR HDRS, & POINT LOADS UNLESS NOTED OTHERWISE * PROVIDE SOLID BLOCKING @ ALL SUPPORT BEAMS, MICROLAMS, & GIRDER TRUSSES TO SUPPORT BELOW 1/4" = 1'-0" 1 Section A 1. CALL FOR INSPECTION TO VERIFY COMPLIANCE WHEN PAPER IS COMPLETE IN ONE WINDOW AREA. 2. WEATHER RESISTIVE BARRIERS: WEATHER RESISTIVE BARRIERS OVER WOOD BASED SHEATHING SHALL INCLUDE 2 LAYERS OF GRADE D PAPER. NOTE TYPE 15 OR 15# FELT IS NOT GRADE D PAPER. VERTICAL JOINTS IN PAPER SHALL BE LAPPED AT LEAST 2 INCHES 3. EXTERIOR OPENINGS FLASHED: EXTERIOR OPENINGS SHALL BE FLASHED. THE NAILING FLANGE ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE MANUFACTURERS INSULATION INSTRUCTIONS ARE PROVIDED ON SITE STATING THE FLANGE IS ACCEPTABLE AS FLASHING. 4. WINDOW FLANGES: PAPER SHALL BE INSTALLED ON THE BOTTOM AND SIDES OF WINDOW BEFORE INSTALLING WINDOW. PAPER ON THE TOP OF WINDOW SHALL GO OVER THE WINDOW FLASHING. A SECOND LAYER OF PAPER SHALL BE INSTALLED OVER THE SIDE WINDOW FLANGES. 5. WINDOW OPENINGS: CAULK OR TAPE WINDOW OPENINGS TO MAKE THEM WATERPROOF OTHER OPENINGS MUST BE CAULKED WEATHERPROOF 6. PAPER ENTIRE WALL: PAPER MUST BE INSTALLED ON THE ENTIRE WALL INCLUDING WITHIN THE SOFFIT FRAMING. ALL PAPER MUST BE INSTALLED SHINGLE FASHION TO DRAIN OUT. 7. FLASHING: KICKOUT FLASHING IS REQUIRED AT ALL WALL/ ROOF INTERSECTIONS WHERE THE ROOF LINE DOES NOT EXTEND PAST THE WALL. OTHER OPENINGS SHALL BE FLASHED TO MAKE WEATHERPROOF. 8. WEEP SCREED: A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE. THE SCREED MUST BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE THE CONCRETE AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR. WEEP SCREEDS MAY BE JUST BELOW THE PLATE LINE OR MAY EXTEND ONTO THE FOUNDATION, PROVIDED THERE IS PAPER ON THE FOUNDATION. STUCCO MUST COVER, BUT NOT EXTEND BELOW, THE LATH AND PAPER. STUCCO/ STONE ATTACHMENT 1/4" = 1'-0" 2 Section B 1/4" = 1'-0" 3 Section C 1/4" = 1'-0" 4 Section D 1/4" = 1'-0" 5 PASSIVE RADON DETAIL 3/8" = 1'-0" 6 WALL DETAIL 3/8" = 1'-0" 7 FLOOR DETAIL 3/8" = 1'-0" 8 WINDOW DETAIL

RkJQdWJsaXNoZXIy NTI3MjQ=